CAT 6A S/FTP 4 PR AWG 23/1

Conductor
Solid copper conductor 23 AWG/1
Insulation
Foam PE
Pair shielding
Aluminium foil
Shielding
Tinned copper wire braid
Sheath
LSZH
Reference standard
IEC 61156-5
ISO/IEC 11801
Core identification
1. White /Blue Stripe & Blue
2. White/Orange Stripe & Orange
3. White/Green Stripe & Green
4. White/Brown Stripe & Brown
Tensile strength
MAX. RECOMMENDED PULLING TENSION: 110 N
Min. Bending Radius (Installation/fixed)
8xØ/ 4 x Ø
Nominal Outer Ø
6.0 ± 0.6 mm
Cable Weight
40 kg/km
Packaging
500 m box
1000 m drum
Fire performance
Dca s2, d2, a1
IEC 60332-1-2
IEC 60332-3-22
Max. Conductor resistance (DC)
93.8 Ω∕km @ 20 °C
Max. Conductor resistance (loop) (pair, max 20 °C) (ohm/km)
max. 19Ω/100m @20 °C
Nom. Mutual capacitance (nF/km)
≤ 5.6 nF/100 m
Capacitance unbalance pair to ground
≤1600 pF/km @1kHz
Min. insulation resistance (20 °C)
5000 MΩxkm
Characteristic impedance
100±25Ω@100 MHz
Rated temperature
75 °C
Operating temperature
-20 – 75 °C

F
(MHz)
ATT
(dB/100 m)
RL
(dB)
NEXT
(dB)
PS NEXT
(dB)
ACRF (EL FEXT)
(dB/100 m)
PS ACRF (PS EL FEXT)
(dB/100 m)
PD
(ns/100 m)
1.0 1.8 26 85 82 85 83 448
4.0 3.4 35 88 83 86 82 443
8.0 4.8 38 86 84 88 82 428
10.0 5.4 36 100 96 95 92 427
16.0 6.9 40 101 98 96 93 425
20.0 7.8 38 101 97 97 93 425
25.0 8.7 41 100 98 95 90 424
31.2 9.8 38 103 100 89 87 423
62.5 14.0 43 101 97 92 88 421
100.0 17.8 42 106 101 85 82 420
200.0 25.2 37 97 94 74 71 419
250.0 28.4 31 99 97 72 70 419
300.0 31.2 32 101 97 71 68 419
400.0 36.0 30 99 96 63 60 419
500.0 40.6 22 96 95 60 58 419