CAT 6 FR S/FTP 4 PR AWG 23/1

Conductor
Solid copper conductor 23 AWG/1
Insulation
Foam PE + mica tape
Pair shielding
Aluminium foil
Shielding
Tinned copper wire braid
Sheath
LSZH (SHF1)
Reference standard
IEC 61156-5
ISO/IEC 11801
Core identification
1. White & Blue
2. White & Orange
3. White & Green
4. White & Brown
Tensile strength
MAX. RECOMMENDED PULLING TENSION: 110 N
Min. Bending Radius (Installation/fixed)
8 xØ
Nominal Outer Ø
9.1 ± 0.6 mm
Cable Weight
94 kg/km
Marine Type Approvals
Pending DNV, LR, RINA
Packaging
500 m box
1000 m drum
Fire performance
IEC 60332-1-2
IEC 60332-3-22
Fire-resistant
IEC 60332-1-2
IEC 60332-3-22 (180 min)
Max. Conductor resistance (DC)
95 Ω∕km @ 20 °C
Max. Conductor resistance (loop) (pair, max 20 °C) (ohm/km)
max. 19Ω/100m @20 °C
Nom. Mutual capacitance (nF/km)
≤ 5.6 nF/100 m
Capacitance unbalance pair to ground
≤1600 pF/km @1kHz
Min. insulation resistance (20 °C)
5000 MΩxkm
Characteristic impedance
100±25Ω@100 MHz
Rated temperature
75 °C
Operating temperature
-20 – 75 °C

F
(MHz)
ATT
(dB/100 m)
RL
(dB)
NEXT
(dB)
PS NEXT
(dB)
ACRF (EL FEXT)
(dB/100 m)
PS ACRF (PS EL FEXT)
(dB/100 m)
PD
(ns/100 m)
4.0 3.2 32 96 88 96 85 497
8.0 4.5 31 91 86 94 87 493
10.0 5.1 33 89 83 92 85 492
16.0 6.5 30 87 78 80 75 490
20.0 7.3 32 88 80 79 74 489
25.0 8.2 34 83 76 76 70 489
31.2 9.2 32 82 75 78 72 488
62.5 13.3 37 78 70 78 70 486
100.0 16.9 34 76 64 73 67 486
200.0 24.7 30 67 60 64 57 485
250.0 28.0 29 66 58 58 52 484