LIFECORD-FRHF (f)

Central Element Glass Fiber (Ø mm)
Ø 3.3 mm
PP-Slotted Core (Ø mm)
Ø 0.8 mm
Optical Fibers
Ø 250 µm
Water Blocking
Water swellable tape
Corrugated steel tape
Sheath
LSZH Thermoplastic
Standard colour red
Reference standard
Helkama specification
Application
Fire-resistant optical fiber cable for indoor application. For fixed installation where the cable has to maintain its functionality during fire.
Tensile strength
Units Mechanical test
2500 N IEC 60794-1-2 E1
Crush strength
Unit Mechanical test
100 mm (PLATE) 7000 N IEC 60794-1-2 E3
25 mm (MANDREL) 1500 N IEC 60794-1-2 E3
Impact strength
Units Mechanical test
50 J IEC 60794-1-2 E4
Min. Bending Radius (Installation/fixed)
(Installation/fixed) 270/200 mm
Nominal Outer Ø
13.5 mm
Cable Weight
196 kg/km
Marine Type Approvals
BV, DNV, RINA
Fire performance
IEC 60332-1-2
IEC 60332-3-22
Fire-resistant
IEC 60331-25 (180 min)
Halogen-free
IEC 60754-1
Smoke emission
IEC 61034 series
Min. installation temperature
-15 ° C
Operating temperature
-30 – 70 °C