Conductor
Stranded copper conductor 26 AWG/7
Insulation
Foam PE
Pair shielding
Aluminium foil
Shielding
Tinned copper wire braid
Sheath
Polyurethane compound
Reference standard
IEC 61156-5
Application
Good mechanical characteristics, high tensile strength, resistant to UV, abrasion, chemicals, oil and other fluids.
Mud resistant according to NEK606. Fully submersible and suitable for permanent underwater installation. Extremely cold resistant, maintains mechanical integrity across an extended operating temperature range of –50 °C to +75 °C, ensuring stable performance in low‑temperature marine and offshore environments, including Arctic‑influenced operational zones. Shielded twisted pair (S/FTP) design to minimize signal interference and attenuation, allowing for clearer signal transmission. Aimed at applications where transmission of frequencies up to 600 MHz is required.
Max. speed 10 Gbps at 30-50 m.
Core identification
1. White /Blue Stripe & Blue2. White/Orange Stripe & Orange3.White/Green Stripe & Green4. White/Brown Stripe & Brown
Tensile strength
MAX. RECOMMENDED 80 NPULLING TENSION
Min. Bending Radius (Installation/fixed)
8xØ
Cable Weight
39 kg/km
Packaging
500 m box, 1000 m drum
Fire performance
IEC 60332-1
Halogen-free
IEC 60754 series
Max. Conductor resistance (DC)
145 Ω∕km @ 20 °C
Max. Conductor resistance (loop) (pair, max 20 °C) (ohm/km)
max. 29Ω/100m @20 °C
Nom. Mutual capacitance (nF/km)
≤ 5.6 nF/100 m
Capacitance unbalance pair to ground
≤1600 pF/km @1kHz
Min. insulation resistance (20 °C)
5000 MΩxkm
Characteristic impedance
100±25Ω@100 MHz
Rated temperature
+75 °C
Operating temperature
-50 °C to +75 °C